• Users Online: 529
  • Print this page
  • Email this page
ARTICLE
Year : 2020  |  Volume : 9  |  Issue : 1  |  Page : 103-120

Development of Wearable IoT-Based Front Kicking Angle Monitoring Device


1 Department of Electronic Engineering, Faculty of Electrical and Electronic Engineering; Senior Researcher, Microelectronics & Nanotechnology-Shamsuddin Research Centre (MiNT-SRC), Institute of Integrated Engineering, Universiti Tun Hussein Onn Malaysia, Malaysia
2 Department of Electronic Engineering, Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, Malaysia

Correspondence Address:
Nur Anida Jumadi
Department of Electronic Engineering, Faculty of Electrical and Electronic Engineering; Senior Researcher, Microelectronics & Nanotechnology-Shamsuddin Research Centre (MiNT-SRC), Institute of Integrated Engineering, Universiti Tun Hussein Onn Malaysia
Malaysia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

In this paper, a wearable front kicking angle monitoring device using flex sensor and Internet of Things (IoT) platform has been successfully developed and tested. The Arduino NodeMCU microcontroller processes and converts the input received from the flex sensor and transmits the real time front kicking angle and corresponding resistance data to the two main outputs; the ThingSpeak IoT platform and the LCD display for real monitoring. Thirty participants were recruited from two different backgrounds; silat athletes (n=20) and non-athlete participants (n=10). The participants were distributed into six weight categories: 50-55 kg, 55-60 kg, 60-65 kg, 65-70 kg, 70-75 kg and 75-80 kg. Based on the average angle measured from three trials, it can be observed that different participants had different averages and standard deviations for front kicking angle independently of weight category. Moreover, the background factor of the subjects involved did not greatly contribute in this research, as the participants from non-athlete background had the highest mean of front kicking angle (73.89 ± 17.41°). This situation is probably due to a lack of standard kicking styles set for all participants at the beginning of the experiment. Nonetheless, one conclusive remark that can be derived from the findings is the front kicking angle of an individual is greatly influenced by body weight, since the (75-80 kg) weight category achieved the lowest mean angle of front kicking for both backgrounds; non-athlete (14.00± 1.33°) and athlete (23.89± 6.44°) subjects. In the future, additional sensors such as accelerometer can be used to predict the stability of the body for better evaluation of front kicking angle.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed412    
    Printed40    
    Emailed0    
    PDF Downloaded59    
    Comments [Add]    

Recommend this journal